THRSimulator - the software for generating radiographs of THR prosthesis


Measuring the orientation of acetabular cup after total hip arthroplasty is important for prognosis. The verification of these measurement methods will be easier and more feasible if we can synthesize prosthesis radiographs in each simulated condition.

One reported method used an expensive mechanical device with an indeterminable precision. We thus develop a program, THR Simulator, to directly synthesize digital radiographs of prostheses for further analysis.Under Windows platform and using Borland C++ Builder programming tool, we developed the THR Simulator.

We first built a mathematical model of acetabulum and femoral head. The data of the real dimension of prosthesis was adopted to generate the radiograph of hip prosthesis.

Then with the ray tracing algorithm, we calculated the thickness each X-ray beam passed, and then transformed to grey scale by mapping function which was derived by fitting the exponential function from the phantom image. Finally we could generate a simulated radiograph for further analysis.

Results: Using THR Simulator, the users can incorporate many parameters together for radiograph synthesis.

These parameters include thickness, film size, tube distance, film distance, anteversion, abduction, upper wear, medial wear, and posterior wear. These parameters are adequate for any radiographic measurement research.

This THR Simulator has been used in two studies, and the errors are within 2o for anteversion and 0.2mm for wearing measurement.

Conclusions: We design a program, THR Simulator that can synthesize prosthesis radiographs. Such a program can be applied in future studies for further analysis and validation of measurement of various parameters of pelvis after total hip arthroplasty.

Author: Tai-Yin Wu, Rong-Sen Yang, Chiou-Shann Fuh, Sheng-Mou Hou and Chen-Kun Liaw
Credits/Source: BMC Musculoskeletal Disorders 2009, 10:8



Published on: 2009-01-17



Copyright by the authors listed above - made available via BioMedCentral (Open Access). Please make sure to read our disclaimer prior to contacting 7thSpace Interactive. To contact our editors, visit our online helpdesk. If you wish submit your own press release, click here.

Social Bookmarking
RETWEET This! | Digg this! | Post to del.icio.us | Post to Furl | Add to Netscape | Add to Yahoo! | Rojo



Comments Page 0 of 0
There are currently 0 comments to display.

 


+ Add New Comment


Custom Search

Username
Password










© 2012 7thSpace Interactive
All Rights Reserved - About | Disclaimer | Helpdesk
There are currently 35122 people browsing 7thSpace