Reconstruction of a maxillary defect with a fibula graft and titanium mesh using CAD/CAM techniques: Case report


We present a case of maxillary and orbital floor reconstruction with a microvascular fibula graft and an individualized titanium mesh. Both were planned virtually; templates were made by rapid prototyping.

The postoperative computertomography scans showed that the planned positions were achieved correctly. This case report illustrates maxillary reconstruction performed with a special template technique and demonstrates the possibilities of computer aided design/ computer aided manufacturing (CAD/CAM) applications in reconstructive surgery.

Author: Bernd LethausPeter KesslerRoland BockmannLucas PoortRene Tolba
Credits/Source: Head &Face Medicine 2010, 6:16



Published on: 2010-07-19



Copyright by the authors listed above - made available via BioMedCentral (Open Access). Please make sure to read our disclaimer prior to contacting 7thSpace Interactive. To contact our editors, visit our online helpdesk. If you wish submit your own press release, click here.