Mandibular reconstruction using an axially vascularized tissue-engineered construct


Current reconstructive techniques for continuity defects of the mandible include the use of free flaps, bone grafts, and alloplastic materials. New methods of regenerative medicine designed to restore tissues depend mainly on the so-called extrinsic neovascularization, where the neovascular bed originates from the periphery of the construct.

This method is not applicable for large defects in irradiated fields.

Methods: We are introducing a new animal model for mandibular reconstruction using intrinsic axial vascularization by the Arterio-Venous (AV) loop. In order to test this model, we made cadaveric, mechanical loading, and surgical pilot studies on adult male goats.

The cadaveric study aimed at defining the best vascular axis to be used in creating the AV loop in the mandibular region. Mechanical loading studies (3 points bending test) were done to ensure that the mechanical properties of the mandible were significantly affected by the designed defect, and to put a base line for further mechanical testing after bone regeneration.

A pilot surgical study was done to ensure smooth operative and post operative procedures.

Results: The best vascular axis to reconstruct defects in the posterior half of the mandible is the facial artery (average length 32.5+/-1.9mm, caliber 2.5mm), and facial vein (average length 33.3+/-1.8mm, caliber 2.6mm). Defects in the anterior half require an additional venous graft.

The defect was shown to be significantly affecting the mechanical properties of the mandible (P value 0.0204).The animal was able to feed on soft diet from the 3rd postoperative day and returned to normal diet within a week. The mandible did not break during the period of follow up (2 months).

Conclusions: Our model introduces the concept of axial vascularization of mandibular constructs.

This model can be used to assess bone regeneration for large bony defects in irradiated fields. This is the first study to introduce the concept of axial vascularization using the AV loop for angiogenesis in the mandibular region.

Moreover, this is the first study aiming at axial vascularization of synthetic tissue engineering constructs at the site of the defect without any need for tissue transfer (in contrast to what was done previously in prefabricated flaps).

Author: Ahmad EweidaAyman NabawiMona MareiMohamed KhalilHabashi Elhammady
Credits/Source: Annals of Surgical Innovation and Research 2011, 5:2



Published on: 2011-03-20



Copyright by the authors listed above - made available via BioMedCentral (Open Access). Please make sure to read our disclaimer prior to contacting 7thSpace Interactive. To contact our editors, visit our online helpdesk. If you wish submit your own press release, click here.

Social Bookmarking
RETWEET This! | Digg this! | Post to del.icio.us | Post to Furl | Add to Netscape | Add to Yahoo! | Rojo



Comments

There are no comments available. Be the first to write a comment.


You need to enable Javascript to post a comment.


Custom Search

Username
Password










© 2013 7thSpace Interactive
All Rights Reserved - About | Disclaimer | Helpdesk
There are currently 55623 people browsing 7thSpace