Real-time cardiovascular magnetic resonance at 1.5 T using balanced SSFP and 40 ms resolution


While cardiovascular magnetic resonance (CMR) commonly employs ECG-synchronized cine acquisitions with balanced steady-state free precession (SSFP) contrast at 1.5 T, recent developments at 3 T demonstrate significant potential for T1-weighted real-time imaging at high spatiotemporal resolution using undersampled radial FLASH. The purpose of this work was to combine both ideas and to evaluate a corresponding real-time CMR method at 1.5 T with SSFP contrast.

Methods: Radial gradient-echo sequences with fully balanced gradients and at least 15-fold undersampling were implemented on two CMR systems with different gradient performance.

Image reconstruction by regularized nonlinear inversion (NLINV) was performed offline and resulted in real-time SSFP CMR images at a nominal resolution of 1.8 mm and with acquisition times of 40 ms.

Results: Studies of healthy subjects demonstrated technical feasibility in terms of robustness and general image quality. Clinical applicability with access to quantitative evaluations (e.g ., ejection fraction) was confirmed by preliminary applications to 27 patients with typical indications for CMR including arrhythmias and abnormal wall motion.

Real-time image quality was slightly lower than for cine SSFP recordings, but considered diagnostic in all cases.

Conclusions: Extending conventional cine approaches, real-time radial SSFP CMR with NLINV reconstruction provides access to individual cardiac cycles and allows for studies of patients with irregular heartbeat.

Author: Dirk VoitShuo ZhangChristina Unterberg-BuchwaldJan M SohnsJoachim LotzJens Frahm
Credits/Source: Journal of Cardiovascular Magnetic Resonance 2013, 15:79



Published on: 2013-09-12



News Provider: 7thSpace Interactive

Copyright by the authors listed above - made available via BioMedCentral (Open Access). Please make sure to read our disclaimer prior to contacting 7thSpace Interactive. To contact our editors, visit our online helpdesk. If you wish submit your own press release, click here.

Social Bookmarking
RETWEET This! | Digg this! | Post to del.icio.us | Post to Furl | Add to Netscape | Add to Yahoo! | Rojo



Comments

There are no comments available. Be the first to write a comment.


You need to enable Javascript to post a comment.


Custom Search

Username
Password










© 2014 7thSpace Interactive
All Rights Reserved - About | Disclaimer | Helpdesk
There are currently 19227 people browsing 7thSpace (S2)